Hanna Conductivity/TDS Meters

Product Description

Hanna's comprehensive line of Conductivity and TDS meters offer dedicated single parameter instruments, as well as multiparameter instruments that support up to eight parameters including salinity and resistivity.

[custom-specifications]
Specifications HI 9034 HI 9835 HI 98360 HI 99300
Image        
Range EC   0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm (actual EC) 0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm (actual EC) 0 to 3999µS/cm
TDS 0.0 to 199.9 mg/L (ppm); 0 to 1999 mg/L (ppm); 0.00 to 19.99 g/L (ppt) 0.00 to 14.99 mg/L (ppm); 15.0 to 149.9 mg/L (ppm); 150 to 1499 mg/L (ppm); 1.50 to 14.99 g/L(ppt); 15.0 to 100.0 g/L (ppt); up to 400.0 g/L (ppt) (actual TDS) with 0.80 conversion factor 0.00 to 14.99 mg/L (ppm); 15.0 to 149.9 mg/L (ppm); 150 to 1499 mg/L (ppm); 1.50 to 14.99 g/L (ppt); 15.0 to 100.0 g/L (ppt); up to 400.0 g/L (ppt) (actual TDS) with 0.80 conversion factor 0 to 2000 ppm (mg/L)
NaCl   0.0 to 400.0% 0.0 to 400.0% 0.0 to 60.0°C/32.0 to 140.0°F
Temperature   -20.0 to 120.0°C (-4.0 to 248.0°F) -20.0 to 120.0°C (-4.0 to 248.0°F)  
Resolution EC   0.01µS/cm; 0.1µS/cm; 1µS/cm; 0.01mS/cm; 0.1mS/cm 0.01µS/cm; 0.1µS/cm; 1µS/cm; 0.01mS/cm; 0.1mS/cm 1µS/cm
TDS 0.1mg/L (ppm); 1mg/L (ppm); 0.01g/L (ppt) 0.01mg/L (ppm); 0.1mg/L (ppm); 1 mg/L(ppm); 0.01 g/L(ppt); 0.1 g/L(ppt) 0.01mg/L (ppm); 0.1mg/L (ppm); 1 mg/L(ppm); 0.01 g/L(ppt); 0.1 g/L(ppt) 1 ppm(mg/L)
NaCl   0.10% 0.10%  
Temperature   0.1°C 0.1°C 0.1°C/0.1°F
Accuracy @ 25°C EC   ±1 % of reading (±0.05µS/cm or 1 digit) ±0.5% of reading ±2% F.S.
TDS   ±1 % of reading (±0.03mg/L (ppm) or 1 digit, whichever greater) ±0.5% of reading ±0.5°C/±1°F
NaCl   ±1% of reading ±0.5% of reading  
Temperature ±1% F.S. (excluding probe error) ±0.2°C (excluding probe error) ±0.2°C (excluding probe error)  
Calibration EC Manual, one point Automatic, one point with six memorized values (84, 1413, 5000, 12880, 80000, 111800µS/cm) Automatic, one point with six memorized values (84, 1413, 5000, 12880, 80000, 111800µS/cm) Automatic, one point at 1413µS/cm, 1382ppm (CONV 0.5) or 1500ppm (CONV 0.7)
NaCl   One point with HI 7037 calibration solution One point with HI 7037 calibration solution  
Temperature Automatic, 0 to 50°C (32 to 122°F) with ß=2%/°C Two point, at 0 and 50°C (32 and 122°F) Two point, at 0 and 50°C (32 and 122°F)  
Temperature Compensation   Automatic or manual from -20.0 to 120.0°C (-4.0 to 248.0°F) (can be disabled for measuring conductivity) Automatic or manual from -20.0 to 120.0°C (-4.0 to 248.0°F) (can be disabled for measuring conductivity) Automatic, 0 to 60°C (32 to 140°F) with ß adjustable from 0.0 to 2.4%/°C with 0.1% step
Temperature Coefficient   Selectable from 0.00 to 6.00%/°C (EC and TDS only); default value is 1.90%/°C Selectable from 0.00 to 6.00%/°C (EC and TDS only); default value is 1.90%/°C Adjustable from 0.45 to 1.00 with 0.01 step (default 0.50)
TDS Factor   Selectable from 0.40 to 0.80 (default value is 0.50) Selectable from 0.40 to 0.80 (default value is 0.50)  
Data Logging     Log on demand, up to 500 samples  
Probe HI 76302W conductivity probe with internal temperature sensor, DIN connector and 1 m (3.3’) cable (included) HI 76309 four ring conductivity probe with internal temperature sensor, DIN connector and 1 m (3.3’) cable (included) HI 76309/1.5 four ring conductivity probe with internal temperature sensor, DIN connector and 1.5 m (4.9’) cable HI 76306 EC/TDS probe with internal temperature sensor, DIN connector and 1 m (3.3’) cable (included)
Power Supply 9V / approximately 100 hours of continuous use 1.5V AAA batteries (3) /approximately 200 hours of continuous use without backlight (50 hours with backlight on); auto-off after 5, 10, 20 and 60 minutes (can be disabled) 1.5V AAA batteries (3) /approximately 200 hours of continuous use without backlight (50 hours with backlight on); auto-off after 5, 10, 20 and 60 minutes (can be disabled) 1.5V AAA (3) / approximately 500 hours of continuous use; auto-off after eight minutes of non-use
Environment 0 to 50°C (32 to 122°F); RH max 100% 0 to 50°C (32 to 122°F); RH max 95% 0 to 50°C (32 to 122°F); RH max 95% 0 to 50°C (32 to 122°F); RH max. 100%
PDF Download Download Download Download
 
 
 
[/custom-specifications]
[custom-features] [/custom-features]
[custom-usage] [/custom-usage]
[custom-documents]Hanna Conductivity/TDS Meters [/custom-documents]
Available Models
Product Features
Applications
Product Documents & Data Sheets
Product Videos
Product Reviews
Write Review

This product hasn't received any reviews yet. Be the first to review this product!

Get a Quote »

Back to Top