call +1 714 432 9996 Get a Quote

LFC3 Hydranautics Membrane

LFC3


Performance

  • Permeate Flow: 9,500 gpd (36 m3/d)
  • Salt Rejection:
  • Nominal 99.7 %

Type
  • Configuration: Spiral Wound
  • Membrane Polymer: Composite Polyamide
  • Neutrally charged
  • Nominal Membrane Area: 400 ft2

Application Data*

  • Maximum Applied Pressure: 600 psig (4.16 MPa)
  • Maximum Chlorine Concentration: < 0.1 PPM
  • Maximum Operating Temperature: 113 oF (45o C)
  • Feedwater pH Range: 3.0 - 10.0
  • Maximum Feedwater Turbidity: 1.0 NTU
  • Maximum Feedwater SDI (15 mins): 5.0
  • Maximum Feed Flow: 75 GPM (17.0 m3/h)
  • Minimum Ratio of Concentrate to
  • Permeate Flow for any Element: 5:1
  • Maximum Pressure Drop for Each Element: 10 psi

* The limitations shown here are for general use. The values may be more conservative for specific projects to ensure the best performance and longest life of the membrane.


Test Conditions

  • The stated performance is initial (data taken after 30 minutes of operation), based on the following conditions:
  • 1500 PPM NaCl solution
  • 225 psi (1.55 MPa) Applied Pressure
  • 77 °F (25 °C) Operating Temperature
  • 15% Permeate Recovery
  • 6.5 - 7.0 pH Range

A, inches (mm) B, inches (mm) C, inches (mm) Weight, lbs. (kg)
40.0 (1016) 7.95 (201.9) 1.125 (28.6) 36 (16.4)