call +1 714 432 9996 Get a Quote

Sub Title: Industrial UV Sterilizers 78 to 1300 GPM Systems

Pure Aqua's UVI systems virtually eliminate microbiological contaminants without using potentially hazardous chemicals. Water enters through the bottom port of the ultraviolet generator cell and swirls around a low pressure mercury vapor lamp, which emits powerful ultraviolet light energy with a 235.7nm wavelength. Bacteria, viruses and other micro-organisms absorb the light energy which disrupts their DNA, and are destroyed safely inside a factory-tested stainless steel holding cell. The treated water then exits through the top port of the cell and is ready for consumption.

SKU: UVI Category: Water Disinfection Systems > Water UV Sterilizers Brand: Pure Aqua Other Names: Ultra Violet Disinfection Unit, UV Sterilizer Machine, Industrial UV Water Treatment System, Ultraviolet Purification System


Uses of Industrial UV Sterilizers UVI 200
  • Effective - Virtually all microorganisms are susceptible to UVI-200 disinfection.
  • Automatic - Continuous or intermittent disinfection without special attention or measurement.
  • Fast - Water is ready for consumption as soon as it leaves the cell, no further contact time needed.
  • Easy - Simple installation and maintenance. Minimum space requirements.
  • Safe - No danger or way of overdosing, no addition of hazardous chemicals.
  • Versatile - Capacities available from 78 to 1,300 gallons per minute.
  • Economical - Hundreds of gallons of water can be purified for just pennies a day.
  • No Chemicals - No chlorine taste or corrosion problems.


Minimum Water Quality Requirements: Operation Specifications:
  • Fe count is less than: 0.3 mg/l
  • H2S count is less than: 0.05 mg/l
  • TSS count is less than: 10 mg/l
  • Mn count is less than: 0.05 mg/l
  • TH level is less than 10 grains per gallon
  • Electrical supply: 100-240V/50-60Hz
  • Max. Operating Pressure: 150 psi (10 bar)
  • Ambient Air: 34-104°F (1-40°C)
  • Water Temperature: 40-104°F (5-40°C)

SPECIFICATIONS SUV-78 SUV-90 SUV-130 SUV-175 SUV-251 SUV-335 SUV-415
Flow Rate (gpm) 78-90 90-115 130-150 175-220 251-300 335-405 415-520
Electrical Volts 120-240V. 120-240V. 120-240V. 120-240V. 120-240V. 120-240V. 120-240V.
Hz 50-60Hz. 50-60Hz. 50-60Hz. 50-60Hz. 50-60Hz. 50-60Hz. 50-60Hz.
Power Consumption(W) 432 336 432 432 672 912 840
Maximum Operating Pressure 10 Bar 10 Bar 10 Bar 10 Bar 10 Bar 10 Bar 10 Bar
150 psi 150 psi 150 psi 150 psi 150 psi 150 psi 150 psi
Ambient Temperature 2-38°C 2-38°C 2-38°C 2-38°C 2-38°C 2-38°C 2-38°C
35-100°F 35-100°F 35-100°F 35-100°F 35-100°F 35-100°F 35-100°F
Lamps/Quartz Sleeves Yes (2) Yes (2) Yes (2) Yes (2) Yes (4) Yes (6) Yes (5)
Inlet/Outlet Port Size 2" Flanged 3" Flanged 3" Flanged 3" Flanged 4" Flanged 4" Flanged 6" Flanged
Hot Water Sanitizable W/Sensor 170°F (77°C) 170°F (77°C) 170°F (77°C) 170°F (77°C) 170°F (77°C) 170°F (77°C) 170°F (77°C)
Gaskets/O-Rings EPDM EPDM EPDM EPDM EPDM EPDM EPDM
Reactor Chamber Material 316L S.S 316L S.S 316L S.S 316L S.S 316L S.S 316L S.S 316L S.S
Control Panel 304 S.S 304 S.S 304 S.S 304 S.S 304 S.S 304 S.S 304 S.S
For more information, please see our PDF in the "Download" tab

SPECIFICATIONS SUV-500 SUV-550 SUV-670 SUV-800 SUV-925 SUV-1100 SUV-1300
Flow Rate (gpm) 500-625 550-700 670-850 800-1070 925-1200 1100-1400 1300
Electrical Volts 120-240V. 120-240V. 120-240V. 120-240V. 120-240V. 120-240V. 120-240V.
Hz 50-60Hz. 50-60Hz. 50-60Hz. 50-60Hz. 50-60Hz. 50-60Hz. 50-60Hz.
Power Consumption(W) 912 1152 1152 1,152 1,152 1,392 1,728
Maximum Operating Pressure 10 Bar 10 Bar 10 Bar 10 Bar 10 Bar 10 Bar 10 Bar
150 psi 150 psi 150 psi 150 psi 150 psi 150 psi 150 psi
Ambient Temperature 2-38°C 2-38°C 2-38°C 2-38°C 2-38°C 2-38°C 2-38°C
35-100°F 35-100°F 35-100°F 35-100°F 35-100°F 35-100°F 35-100°F
Lamps/Quartz Sleeves Yes (6) Yes (8) Yes (8) Yes (8) Yes (8) Yes (10) Yes (12)
Inlet/Outlet Port Size 6" Flanged 6" Flanged 6" Flanged 8" Flanged 8" Flanged 8" Flanged 8" Flanged
Hot Water Sanitizable W/Sensor 170°F (77°C) 170°F (77°C) 170°F (77°C) 170°F (77°C) 170°F (77°C) 170°F (77°C) 170°F (77°C)
Gaskets/O-Rings EPDM EPDM EPDM EPDM EPDM EPDM EPDM
Reactor Chamber Material 316L S.S 316L S.S 316L S.S 316L S.S 316L S.S 316L S.S 316L S.S
Control Panel 304 S.S 304 S.S 304 S.S 304 S.S 304 S.S 304 S.S 304 S.S
For more information, please see our PDF in the "Download" tab


Standard Features: Available Options:
  • High output low pressure mercury vapor lamps with high isolation pin design
  • Easy servicing - no need to disconnect the inlet water to change the UV lamp
  • Solenoid output works in conjunction with the ultraviolet alarm, allowing for the stoppage of water flow in the event of low water quality or in case of a power failure
  • 99.9% kill rate on bacteria and viruses
  • Stainless steel or aluminum housing
  • Seven year warranty on reactor chamber
  • Includes mounting clamp and quarts sleeve
  • 316 stainless steel reactor chamber
  • Lamp failure, power, and total run-time indicators
  • True 254nm ultraviolet sensor incorporating individual calibration boards with audible and visual indicators included
  • Quartz sleeve and aluminum gland nuts for optimal operating temperature and sealing
  • Remote plug-in and desktop ballast
  • Infrared output allows for remote monitoring as well as diagnostic tools for service technicians. For remote audible and visual monitoring of the UV sensor, use the optional IR-ALARM
  • Hot water sanitization at 170°F (77°C)


The ultraviolet method of microbiological eradication is commonly used for:
  • Homes
  • Hotels
  • Schools
  • Green Houses
  • Beauty Shops
  • Cottages
  • Farms
  • Hospitals